Preparation
C² Remove
Cleaner for removing waxes, acrylics, curing agents and tyre marks before concrete treatment.
Why choose C²? →Stock availability
Contact us for availability

When to choose this product
For concrete before grinding, polishing, hardening or protective treatment. Removes floor waxes, acrylic treatments, curing compounds and tyre marks that interfere with preparation.
Product advantages
- A preparation cleaner for grinding, polishing, hardening, densifying, and the application of other penetrating protective treatments.
- Quickly removes floor waxes, acrylics, curing agents and tire/scuff marks from concrete.
- Can be used as concentrate or diluted with fresh water, depending on the requirements.
More advantages
- Low-odor, water-rinsable cleaner containing readily biodegradable materials. Does not change concrete color.
Technical information
Typical technical data
| Appearance | Clear, colorless liquid |
|---|---|
| Specific gravity | 1.05 |
| pH | Not applicable |
| Active content | Not applicable |
| Total solids | Not applicable |
| VOC content | 4% max. |
| Shelf life in a tightly sealed, unopened container | 2 years |
| Flash point | >93 °C (ASTM D3278) |
Typical values from the manufacturer’s TDS; application details are in the full instructions.
Preparation and working conditions
Sweep away loose debris and protect glass and metal. Use above 4°C, preferably above 10°C. For light wax dilute 1 part product with 10 parts water; for heavy wax use 1:3. For low-solids curing/sealing films use undiluted.
Do not apply below 4°C. Cleaning is more effective at 10°C and above; allow frozen concrete to thaw before work.
Equipment
Apply with a brush, mop or pump sprayer. Lift spent cleaner and loosened coating with a mop or wet vacuum.
Practical advice
Test a representative area with the equipment and preparation planned for the job. Let it dry before assessing the result and coverage.
Collect the used cleaner and loosened coating with a wet vacuum or mop. Rinse with fresh water if residue remains and let the surface dry before the next treatment.
Clean tools with fresh water before the product dries. Immediately wash splashes off glass, aluminium and other adjacent surfaces.
Storage and handling
Storage temperature7–38 °C
Store upright in sealed original containers in a cool, dry place. Close after dispensing. Follow local rules for unused product and packaging.
Choose products for your floor